With the green EV revolution outburst, consumers have become even more conscious towards the environment and invested in electric vehicles. However, the concern for recharging their EVs hasn’t diminished yet. Bacancy brings in a top-notch solution to your consumers’ troubles.
We present our 6 variants of AC charge controllers AC input having distinct properties to meet modern day EV charge solutions.
Connect with our product expertSpecifications | Hybrid AC Charger Controller |
Input Voltage | 415 VAC +/- 10 % Three Phase |
AC Input Connection | 3P + N + PE |
Frequency | 50 Hz |
AC Output Current | 16A X 2(IEC 60309) & 32A X 1(IEC 62196-2) |
Maximum Output Power | 3.3kW X 2(IEC 60309) & 7.4kW X 1(IEC 62196-2) |
Connector Type | IEC 60309 Industrial Socket & Type2 AC |
Number of Connector | 3 |
Protection | Overcurrent, overvoltage, undervoltage, Short circuit, Surge Protection (SPD), Earth leakage protection(RCD Interface & RCCB Type B) |
Display | 20 * 4 Character LCD Display as well as TFT 4.3” LCD supported |
Visual Indication LED’s | Presence of Input Supply, Errors Indicator, State of Charge. |
Communication Charger and CMS | OCPP v 1.6 or above - Ethernet (Standard) or Optical GSM Modem (2G/3G/4G) and Wi-Fi |
Energy Measurement | Internal Metering with lnbuild CT supported |
Specifications | AC Single Gun Type 2 (7.4Kw Controller) |
Input Voltage | 220 VAC +/- 10 % Single Phase |
AC Input Connection | P + N + PE |
Frequency | 50 Hz |
AC Output Current | 32 A |
Maximum Output Power | 7.2 kW |
Connector Type | Type 2 |
Number of Connector | One |
Protection | Overcurrent, overvoltage, undervoltage, Short circuit, Surge Protection (SPD), Earth leakage protection(RCD Interface & RCCB Type B) |
Display | 20 * 4 Character LCD Display as well as TFT 4.3” LCD supported |
Visual Indication LED’s | Presence of Input Supply, Errors Indicator, State of Charge. |
Communication Charger and CMS | Communication Network : GSM Modem(4G LTE fall-back to 2G) and Wi-Fi |
Energy Measurement | Internal Metering with lnbuild CT supported |
Specifications | AC Dual Gun Type 2 Controller |
Input Voltage | 415 VAC +/- 10 % Three Phase |
AC Input Connection | 3P + N + PE |
Frequency | 50 Hz |
AC Output Current | 32 A (2 Sets) |
Maximum Output Power | 7.2 kW (2 Sets) |
Connector Type | Type 2 |
Number of Connector | 2 |
Protection | Overcurrent, overvoltage, undervoltage, Short circuit, Surge Protection (SPD), Earth leakage protection(RCD Interface & RCCB Type B) |
Display | 20 * 4 Character LCD Display as well as TFT 4.3” LCD supported |
Visual Indication LED’s | Presence of Input Supply, Errors Indicator, State of Charge. |
Communication Charger and CMS | Communication Network : GSM Modem(4G LTE fall-back to 2G) and Wi-Fi |
Energy Measurement | Internal Metering with lnbuild CT supported |
Specifications | AC Single Gun Type 2 (22KW) |
Input Voltage | 415 VAC +/- 10 % Three Phase |
AC Input Connection | 3P + N + PE |
Frequency | 50 Hz |
AC Output Current | 32A for Each phase |
Maximum Output Power | 22 kW |
Connector Type | Type 2 |
Number of Connector | One |
Protection | Overcurrent, overvoltage, undervoltage, Short circuit, Surge Protection (SPD), Earth leakage protection(RCD Interface & RCCB Type B) |
Display | 20 * 4 Character LCD Display as well as TFT 4.3” LCD supported |
Visual Indication LED’s | Presence of Input Supply, Errors Indicator, State of Charge. |
Communication Charger and CMS | OCPP v 1.6 or above - Ethernet (Standard) or Optical GSM Modem (2G/3G/4G) and Wi-Fi |
Energy Measurement | Internal Metering with lnbuild CT supported |
Specifications | Bharat AC001 Controller |
Input Voltage | 415 VAC +/- 10 % Three Phase |
AC Input Connection | 3P + N + PE |
Frequency | 50 Hz |
AC Output Current | 16 A in each Output |
Maximum Output Power | 3.3kW in each Output |
Connector Type | IEC 60309 Industrial Socket |
Number of Connector | 3 |
Protection | Overcurrent, overvoltage, undervoltage, Short circuit, Surge Protection (SPD), Earth leakage protection(RCD Interface & RCCB Type B) |
Display | 4.3" Graphical LCD Display |
Visual Indication LED’s | Presence of Input Supply, Errors Indicator, State of Charge. |
Communication Charger and CMS | Communication Network : GSM Modem(4G LTE fall-back to 2G) and Wi-Fi |
Energy Measurement | Internal (lnbuild CT) & External (Energy meter with Modbus) |
Specifications | AC Controller |
Input Voltage | 230/240 VAC +/- 10 % Single Phase |
AC Input Connection | P + N + PE |
Frequency | 50 Hz |
AC Output Current | 30 A |
Maximum Output Power | 7.2 kW |
Connector Type | IEC 60309 Industrial Socket |
Number of Connector | One |
Protection | Overcurrent, overvoltage, undervoltage, Short circuit, Surge Protection (SPD), Earth leakage protection(RCD Interface & RCCB Type B) |
Display | 1.3" OLED |
Push Button | Emergency Stop |
Communication Charger | BLE/ Wi-Fi |
Energy Measurement | Internal Metering with lnbuild CT supported |
Your Success Is Guaranteed !